Voltage transformer
+
  • Voltage transformer
Product Application

This type of voltage transformer is used for voltage and energy measurement, monitoring and power control in three-phase lines with an AC frequency of 50Hz and a rated voltage of 10kV. It is suitable for outdoor vacuum circuit breakers and can also be used in small transformers and distribution stations in industrialenterprises.

 

Implementation Standards

GB20840.3-2013

 

Conditions of Use

● Ambient temperature between -40℃ and 70℃, with a daily average temperature not exceeding 35℃. 
● No significant dust, smoke, corrosive gases, steam, or salt contamination. 
● Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%. 
● Altitude not exceeding 1000 meters.

 

Technical Parameters Table
ModelRated Voltage Ratio (kV)Accuracy Class and Accuracy Class CombinationRated Secondary Output (VA)Thermal Limit Output (VA)Rated Insulation Level (kV)
JDZ(W)-3R3/0.10.2
0.5
1
3
154003.6/25/40
JDZ(W)-6R6/0.1307.2/32/60
JDZ(W)-10R10/0.16012/42/75
150
10/0.1/0.10.2/0.510/15200
10/0.1/0.220.5/330/150200/350

 

External Dimensions Diagram

Keywords

Voltage transformer
+
  • Voltage transformer

Voltage transformer

This type of voltage transformer is for AC 50Hz, rated voltage 10kV three-phase lines, for voltage energy measurement monitoring and control power supply, suitable for outdoor vacuum circuit breakers, and can also be used in industrial enterprises small substations.


Product Application

This type of voltage transformer is used for voltage and energy measurement, monitoring and power control in three-phase lines with an AC frequency of 50Hz and a rated voltage of 10kV. It is suitable for outdoor vacuum circuit breakers and can also be used in small transformers and distribution stations in industrialenterprises.

 

Implementation Standards

GB20840.3-2013

 

Conditions of Use

● Ambient temperature between -40℃ and 70℃, with a daily average temperature not exceeding 35℃. 
● No significant dust, smoke, corrosive gases, steam, or salt contamination. 
● Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%. 
● Altitude not exceeding 1000 meters.

 

Technical Parameters Table
ModelRated Voltage Ratio (kV)Accuracy Class and Accuracy Class CombinationRated Secondary Output (VA)Thermal Limit Output (VA)Rated Insulation Level (kV)
JDZ(W)-3R3/0.10.2
0.5
1
3
154003.6/25/40
JDZ(W)-6R6/0.1307.2/32/60
JDZ(W)-10R10/0.16012/42/75
150
10/0.1/0.10.2/0.510/15200
10/0.1/0.220.5/330/150200/350

 

External Dimensions Diagram

Get a Quote

Through the previous introduction, we believe you have learned enough about us and are confident to cooperate with us. Please leave your information quickly, and we will send you samples or brochures!

视频标题

Get a Quote

Through the previous introduction, we believe you have learned enough about us and are confident to cooperate with us. Please leave your information quickly, We will contact you within 24 hours.

Submit