Product Application
This product is a three-phase five-column voltage transformer designed by the State Grid standard. It adopts the
4PT anti-ferromagnetic resonance principle. When the system has grounding faults of varying degrees, no resonance will occur, and it can run for a long time. The primary terminal is used in conjunction with the American 200A largediameter shaft type, and a special fuse is installed in the plug. It is used in indoor AC 50 or 60Hz, rated voltage 10kV power system to provide 220V power supply, voltage measurement and zero-sequence protection.
Implementation Standards
GB20840.3-2013
Conditions of Use
● Ambient temperature between -40℃ and 70℃, with a daily average temperature not exceeding 35℃.
● No significant dust, smoke, corrosive gases, steam, or salt contamination.
● Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%.
● Altitude not exceeding 1000 meters.
Wiring Diagram

Technical Parameters Table
| Model | Rated Voltage Ratio (kV) | Accuracy Class and Accuracy Class Combination | Rated Secondary Output (VA) | Thermal Limit Output (VA) | Rated Insulation Level (kV) |
| JSZV12A-10R1 | 10/√3/0.1/√3/0.1 | 3/6P(3P) | 3X500/100 | 3×300/300 | 12/42/75 |
| JSZV12A-6R1 | 6/√3/0.1/√3/0.1 | 0.5/3/6P(3P) | 3X30/3X300/50 | 3X300/3X300 | 12/42/75 |
| JSZV12A-10R1 | 100/3/0.1/3/0.1 | 0.5/3/6P(3P) | 3X25/3X300/100 | 3X300/3X500 | 12/42/75 |
Dimensional Drawing

Keywords
Three-phase five-column anti-resonance voltage transformer for ring main unit
Contact Us
Category
Product Application
This product is a three-phase five-column voltage transformer designed by the State Grid standard. It adopts the
4PT anti-ferromagnetic resonance principle. When the system has grounding faults of varying degrees, no resonance will occur, and it can run for a long time. The primary terminal is used in conjunction with the American 200A largediameter shaft type, and a special fuse is installed in the plug. It is used in indoor AC 50 or 60Hz, rated voltage 10kV power system to provide 220V power supply, voltage measurement and zero-sequence protection.
Implementation Standards
GB20840.3-2013
Conditions of Use
● Ambient temperature between -40℃ and 70℃, with a daily average temperature not exceeding 35℃.
● No significant dust, smoke, corrosive gases, steam, or salt contamination.
● Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%.
● Altitude not exceeding 1000 meters.
Wiring Diagram

Technical Parameters Table
| Model | Rated Voltage Ratio (kV) | Accuracy Class and Accuracy Class Combination | Rated Secondary Output (VA) | Thermal Limit Output (VA) | Rated Insulation Level (kV) |
| JSZV12A-10R1 | 10/√3/0.1/√3/0.1 | 3/6P(3P) | 3X500/100 | 3×300/300 | 12/42/75 |
| JSZV12A-6R1 | 6/√3/0.1/√3/0.1 | 0.5/3/6P(3P) | 3X30/3X300/50 | 3X300/3X300 | 12/42/75 |
| JSZV12A-10R1 | 100/3/0.1/3/0.1 | 0.5/3/6P(3P) | 3X25/3X300/100 | 3X300/3X500 | 12/42/75 |
Dimensional Drawing

Get a Quote
Through the previous introduction, we believe you have learned enough about us and are confident to cooperate with us. Please leave your information quickly, and we will send you samples or brochures!
Other Products