current transformer
+
  • current transformer
Product Application

LZZBJ9-35 current transformer is an indoor epoxy resin cast pillar-type full-duty product. It is used for relay protection and electric energy measurement in power systems with a rated frequency of 50Hz and a rated voltage of 35kV and below. LZZBJ9-35 is installed in a center-mounted switchgear or other types of switchgear.

 

Implementation Standards

GB/T20840.2-2014

 

Operating Conditions

● Ambient temperature between -40℃ and 70℃, with a daily average temperature not exceeding 35℃. 
● No significant dust, smoke, corrosive gases, steam, or salt contamination. 
● Relative humidity: Daily average not exceeding 95%, monthly average not exceeding 90%. 
● Altitude not exceeding 1000 meters.

 

Technical Parameters Table

Rated Secondary Current: 5A, 1A

Rated Primary Current (A)Accuracy Class CombinationRated Output (VA)Rated Thermal Current (kA/1S)Rated Dynamic Stability Current (kA)
0.20.510P1010P1510P20
30 - 1000.2/10P10/10P10
0.2/10P15/10P15 
0.2/10P10/10P20 
0.2/10P15/10P20 
0.5/10P10/10P10 
0.5/10P15/10P15 
0.5/10P10/10P20 
0.5/10P15/10P20
1530503020150l1n/2375l1n
15031.5/180
20031.5/280
300 - 500153050302031.5/380
600 - 80031.5/480
1000 - 31503050504030
405050503040/4100
 
Dimensions

Keywords

current transformer
+
  • current transformer

current transformer

The LZZBJ9-35 current transformer is an indoor epoxy resin-cast, pillar-type, full-condition product. It is used for relay protection and energy measurement in power systems with a rated frequency of 50Hz and a rated voltage of 35kV or less. The LZZBJ9-35 is installed in a center-mounted switchgear or other types of switchgear.


Product Application

LZZBJ9-35 current transformer is an indoor epoxy resin cast pillar-type full-duty product. It is used for relay protection and electric energy measurement in power systems with a rated frequency of 50Hz and a rated voltage of 35kV and below. LZZBJ9-35 is installed in a center-mounted switchgear or other types of switchgear.

 

Implementation Standards

GB/T20840.2-2014

 

Operating Conditions

● Ambient temperature between -40℃ and 70℃, with a daily average temperature not exceeding 35℃. 
● No significant dust, smoke, corrosive gases, steam, or salt contamination. 
● Relative humidity: Daily average not exceeding 95%, monthly average not exceeding 90%. 
● Altitude not exceeding 1000 meters.

 

Technical Parameters Table

Rated Secondary Current: 5A, 1A

Rated Primary Current (A)Accuracy Class CombinationRated Output (VA)Rated Thermal Current (kA/1S)Rated Dynamic Stability Current (kA)
0.20.510P1010P1510P20
30 - 1000.2/10P10/10P10
0.2/10P15/10P15 
0.2/10P10/10P20 
0.2/10P15/10P20 
0.5/10P10/10P10 
0.5/10P15/10P15 
0.5/10P10/10P20 
0.5/10P15/10P20
1530503020150l1n/2375l1n
15031.5/180
20031.5/280
300 - 500153050302031.5/380
600 - 80031.5/480
1000 - 31503050504030