current transformer for measurement
+
  • current transformer for measurement
Product Application

LJZN1-10 current transformer is an indoor epoxy resin cast pillar type full-duty product. It is used for electric energy measurement in power systems with a rated frequency of 50Hz and a rated voltage of 10kV and below. It is installed in a center-mounted switchgear or other types of switchgear.

 

Implementation Standard

GB/T20840.2-2014

 

Conditions of Use

● Ambient temperature between -40℃ and 70℃, with a daily average temperature not exceeding 35℃. 
● No significant dust, smoke, corrosive gases, steam, or salt contamination. 
● Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%. 
● Altitude not exceeding 1000 meters.

 

Technical Parameters

● Rated insulation level: 12/42/75kV 
● Rated secondary current: 5A or 1A 
● Power factor of the load: cosΦ=0.8 (lagging) 
● Creepage distance: Meets Class II pollution level requirements 
● State Grid Standard: Q/GDW10572.2-2023 
● Instrument safety factor: FS ≤ 5

 

Technical Parameter Table

Rated secondary current: 5A, 1A

Rated primary current (A)Rated short-time thermal current (KA effective value)Rated dynamic stability current (KA peak value)Accuracy classRated secondary output (VA)Creepage distance (mm)Weight (kg)
205/2S12.50.2S
0.5S
1524011
308/2S20
408/2S20
5010/2S25
6010/2S25
7516/2S40
10020/2S50
15020/2S50
20020/2S50
30025/4S63
40025/4S63
50025/4S63
60031.5/4S80
75031.5/4S80

 

Dimensional drawing

Keywords

current transformer for measurement
+
  • current transformer for measurement

current transformer for measurement

The LJZN1-10 current transformer is an indoor epoxy resin-cast, pillar-type, full-condition product. It is used for electrical energy measurement in power systems with a rated frequency of 50Hz and a rated voltage of 10kV or less, and is installed in a center-mounted switchgear or other types of switchgear.


Product Application

LJZN1-10 current transformer is an indoor epoxy resin cast pillar type full-duty product. It is used for electric energy measurement in power systems with a rated frequency of 50Hz and a rated voltage of 10kV and below. It is installed in a center-mounted switchgear or other types of switchgear.

 

Implementation Standard

GB/T20840.2-2014

 

Conditions of Use

● Ambient temperature between -40℃ and 70℃, with a daily average temperature not exceeding 35℃. 
● No significant dust, smoke, corrosive gases, steam, or salt contamination. 
● Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%. 
● Altitude not exceeding 1000 meters.

 

Technical Parameters

● Rated insulation level: 12/42/75kV 
● Rated secondary current: 5A or 1A 
● Power factor of the load: cosΦ=0.8 (lagging) 
● Creepage distance: Meets Class II pollution level requirements 
● State Grid Standard: Q/GDW10572.2-2023 
● Instrument safety factor: FS ≤ 5

 

Technical Parameter Table

Rated secondary current: 5A, 1A

Rated primary current (A)Rated short-time thermal current (KA effective value)Rated dynamic stability current (KA peak value)Accuracy classRated secondary output (VA)Creepage distance (mm)Weight (kg)
205/2S12.50.2S
0.5S
1524011
308/2S20
408/2S20
5010/2S25
6010/2S25
7516/2S40
10020/2S50
15020/2S50
20020/2S50
30025/4S63
40025/4S63
50025/4S63
60031.5/4S80
75031.5/4S80

 

Dimensional drawing

Get a Quote

Through the previous introduction, we believe you have learned enough about us and are confident to cooperate with us. Please leave your information quickly, and we will send you samples or brochures!

视频标题

Get a Quote

Through the previous introduction, we believe you have learned enough about us and are confident to cooperate with us. Please leave your information quickly, We will contact you within 24 hours.

Submit
google-site-verification: google90f4f2a4fbaac814.html