550 cabinet current transformer
+
  • 550 cabinet current transformer
Product Overview

LZZB9-10G2 current transformer is an indoor epoxy resin cast pillar type full-duty product. It is used for relay 
protection and electric energy measurement in power systems with a rated frequency of 50Hz and a rated voltage of 10kV and below. It is installed in a center-mounted switchgear or other types of switchgear.

 

Product Features

 

Operating Conditions

● Ambient temperature between -40℃ and 70℃, with a daily average temperature not exceeding 35℃. 
● No significant dust, smoke, corrosive gases, steam, or salt contamination. 
● Relative humidity: Daily average not exceeding 95%, monthly average not exceeding 90%. 
● Altitude not exceeding 1000 meters.

Technical Parameters
● Rated insulation level: 12/42/75kV
● Rated secondary current: 5A or 1A
● Power factor of the load: cosΦ=0.8 (lagging)
● Creepage distance: Meets Class II pollution level requirements
● State Grid Standard: JJG313-2010
● Instrument safety factor: FS ≤ 5

 

Implementation Standards

GB/T20840.2-2014

 

Technical Parameter Table

 

 

Rated Primary Current (A)Rated Short-Time Thermal Current (KA effective value)Rated Dynamic Stability Current (KA peak value)Accuracy Class CombinationRated Secondary Output (VA)Creepage Distance (mm)Weight (kg)
101.53.750.2S/0.2S
0.2S/EP
15151524522
1525
2037.5
253.759
304.511.25
40615
507.518
7511.2528
100 - 2003075
30045100
40045100
50056100
60056100
75063110
100080110
125090130
1500100130

 

Dimensional Drawing

Keywords

550 cabinet current transformer
+
  • 550 cabinet current transformer

550 cabinet current transformer

The LZZBJ9-10C2 current transformer is an indoor epoxy resin-cast, pillar-type, all-condition product. It is used for relay protection and energy measurement in power systems with a rated frequency of 50Hz and a rated voltage of 10kV or less. The LZZBJ9-C2 is installed in a center-mounted switchgear or other types of switchgear.


Product Overview

LZZB9-10G2 current transformer is an indoor epoxy resin cast pillar type full-duty product. It is used for relay 
protection and electric energy measurement in power systems with a rated frequency of 50Hz and a rated voltage of 10kV and below. It is installed in a center-mounted switchgear or other types of switchgear.

 

Product Features

 

Operating Conditions

● Ambient temperature between -40℃ and 70℃, with a daily average temperature not exceeding 35℃. 
● No significant dust, smoke, corrosive gases, steam, or salt contamination. 
● Relative humidity: Daily average not exceeding 95%, monthly average not exceeding 90%. 
● Altitude not exceeding 1000 meters.

Technical Parameters
● Rated insulation level: 12/42/75kV
● Rated secondary current: 5A or 1A
● Power factor of the load: cosΦ=0.8 (lagging)
● Creepage distance: Meets Class II pollution level requirements
● State Grid Standard: JJG313-2010
● Instrument safety factor: FS ≤ 5

 

Implementation Standards

GB/T20840.2-2014

 

Technical Parameter Table

 

 

Rated Primary Current (A)Rated Short-Time Thermal Current (KA effective value)Rated Dynamic Stability Current (KA peak value)Accuracy Class CombinationRated Secondary Output (VA)Creepage Distance (mm)Weight (kg)
101.53.750.2S/0.2S
0.2S/EP
15151524522
1525
2037.5
253.759
304.511.25
40615
507.518
7511.2528
100 - 2003075
30045100
40045100
50056100
60056100
75063110
100080110
125090130
1500100130

 

Dimensional Drawing

Get a Quote

Through the previous introduction, we believe you have learned enough about us and are confident to cooperate with us. Please leave your information quickly, and we will send you samples or brochures!

视频标题

Get a Quote

Through the previous introduction, we believe you have learned enough about us and are confident to cooperate with us. Please leave your information quickly, We will contact you within 24 hours.

Submit
google-site-verification: google90f4f2a4fbaac814.html