current transformer
+
  • current transformer
Product Overview

LZZBJ9-10 current transformer is an indoor epoxy resin cast pillar type full-duty product. It is used for relay protection and electric energy measurement in power systems with a rated frequency of 50Hz and a rated voltage of 10kV and below. It is installed in a center-mounted switchgear or other types of switchgear.

 

Product Features

 

Conditions of Use

● Ambient temperature between -40℃ and 70℃, with a daily average temperature not exceeding 35℃. 
● No significant dust, smoke, corrosive gases, steam, or salt contamination. 
● Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%. 
● Altitude not exceeding 1000 meters.

 

Implementation Standards

GB/T20840.2-2014

 

Technical Parameters Table 
 
Rated Primary Current (A)Accuracy Class CombinationRated Output (VA)Rated Thermal Current (kA/1S)Rated Dynamic Stability Current (kA)
100.2S/10P10
0.5/10P10 
0.2S/10P15 
0.5/10P15 
0.2S/0.5/10P10 
0.2S/10P10/10P10 
0.2S/0.5/10P15 
0.2S/10P15/10P15
10/15 
10/15 
10/15 
15/15
12.5
151.53.8
20,252.56.3
3034.5
40410
50,606.315.8
757.518.7
1001025
1501537.5
200,2502563
3003075
400-63072100
750-1250100130
1500-3150100160

 

Dimensional Drawing

Keywords

current transformer
+
  • current transformer

current transformer

The LZZBJ9-10 current transformer is an indoor epoxy resin-cast, pillar-type, full-condition product. It is used for relay protection and energy measurement in power systems with a rated frequency of 50Hz and a rated voltage of 10kV or less, and is installed in a central-type switchgear or other types of switchgear.


Product Overview

LZZBJ9-10 current transformer is an indoor epoxy resin cast pillar type full-duty product. It is used for relay protection and electric energy measurement in power systems with a rated frequency of 50Hz and a rated voltage of 10kV and below. It is installed in a center-mounted switchgear or other types of switchgear.

 

Product Features

 

Conditions of Use

● Ambient temperature between -40℃ and 70℃, with a daily average temperature not exceeding 35℃. 
● No significant dust, smoke, corrosive gases, steam, or salt contamination. 
● Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%. 
● Altitude not exceeding 1000 meters.

 

Implementation Standards

GB/T20840.2-2014

 

Technical Parameters Table 
 
Rated Primary Current (A)Accuracy Class CombinationRated Output (VA)Rated Thermal Current (kA/1S)Rated Dynamic Stability Current (kA)
100.2S/10P10
0.5/10P10 
0.2S/10P15 
0.5/10P15 
0.2S/0.5/10P10 
0.2S/10P10/10P10 
0.2S/0.5/10P15 
0.2S/10P15/10P15
10/15 
10/15 
10/15 
15/15
12.5
151.53.8
20,252.56.3
3034.5
40410
50,606.315.8
757.518.7
1001025
1501537.5
200,2502563
3003075
400-63072100
750-1250100130