indoor three-phase integrated current transformer
+
  • indoor three-phase integrated current transformer
Product Application

The LSZ series three-phase integrated current transformer is installed at the root of the inlet and outlet bushings of the fully insulated and fully sealed ring main unit and the pole-mounted switchgear, fixed with bolts, and integrated with the complete set of equipment. The overall structure is compact, light, and easy to install. All installation work is completed in the factory of the complete set of equipment. No secondary installation is required on site. When 
the complete set of equipment is modified, there is no need to remove the cable accessories, which reduces the 
modification cost. It is neat and beautiful, and maintenance-free when leaving the factory. It can provide a variety of phase sequence and zero sequence current measurement/metering and protection combination solutions, which have been used in compact fully insulated and fully sealed ring network switchgear and pole-mounted switches and other electrical equipment.

 

 

Implementation Standards

GB/T20840.2-2014

 

Conditions of Use

● Ambient temperature: -25℃ ~ +40℃, daily average temperature not exceeding 35℃; 
● No obvious dust, smoke, corrosive gases, steam or salt spray, etc.; 
● Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%; 
● Altitude: not exceeding 1000m.

 

Wiring Diagram
Product Dimensions

Ф77×H65×L107

 

Technical Parameters

● Rated frequency: 50Hz/60Hz 
● Rated secondary current: 5A/1A 
● Rated continuous thermal current: 120%In 
● Power frequency withstand voltage: 3kV/1min/50Hz 
● Instrument safety factor: FS ≤ 10

Technical Parameter Table

 

Product Category

Measuring Current Transformer

Protection Current Transformer

Rated Current Ratio 1/2

Accuracy Class and Rated Burden

0.5

1.0

3

10P15

10P10

200/1

 

2.5

3.75

 

1

300/1

2

3.75

5

1

1.5

400/1

3.75

7.5

7.5

1.5

2

500/1

5

10

12.5

1.5

2

600/1

7.5

10

12.5

2

2.5

200/5

 

2.5

3.75

 

 

300/5

1.5

3.75

5

 

 

400/5

2.5

7.5

7.5

 

 

500/5

5

10

12.5

1

1.5

600/5

7.5

10

12.5

2

2.5

Keywords

indoor three-phase integrated current transformer
+
  • indoor three-phase integrated current transformer

indoor three-phase integrated current transformer

The LSZ series three-phase integrated current transformer is installed at the base of the cable bushing of fully insulated and sealed ring network cabinets and pole-mounted switchgear, fixed with bolts, and integrated with the complete equipment. The overall structure is compact, lightweight, and easy to install. All installation work is completed in the factory of the complete equipment, and no secondary installation is required on site. When the complete equipment is modified, there is no need to remove the cable accessories, which reduces the modification cost, is clean and beautiful, and is maintenance-free upon leaving the factory. It can provide a variety of phase sequence and zero-sequence current measurement/metering and protection combination schemes, and has been applied in compact fully insulated and sealed ring network switchgear and pole-mounted switches and other electrical equipment.


Product Application

The LSZ series three-phase integrated current transformer is installed at the root of the inlet and outlet bushings of the fully insulated and fully sealed ring main unit and the pole-mounted switchgear, fixed with bolts, and integrated with the complete set of equipment. The overall structure is compact, light, and easy to install. All installation work is completed in the factory of the complete set of equipment. No secondary installation is required on site. When 
the complete set of equipment is modified, there is no need to remove the cable accessories, which reduces the 
modification cost. It is neat and beautiful, and maintenance-free when leaving the factory. It can provide a variety of phase sequence and zero sequence current measurement/metering and protection combination solutions, which have been used in compact fully insulated and fully sealed ring network switchgear and pole-mounted switches and other electrical equipment.

 

 

Implementation Standards

GB/T20840.2-2014

 

Conditions of Use

● Ambient temperature: -25℃ ~ +40℃, daily average temperature not exceeding 35℃; 
● No obvious dust, smoke, corrosive gases, steam or salt spray, etc.; 
● Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%; 
● Altitude: not exceeding 1000m.

 

Wiring Diagram
Product Dimensions

Ф77×H65×L107

 

Technical Parameters

● Rated frequency: 50Hz/60Hz 
● Rated secondary current: 5A/1A 
● Rated continuous thermal current: 120%In 
● Power frequency withstand voltage: 3kV/1min/50Hz 
● Instrument safety factor: FS ≤ 10

Technical Parameter Table

 

Product Category

Measuring Current Transformer

Protection Current Transformer

Rated Current Ratio 1/2

Accuracy Class and Rated Burden

0.5

1.0

3

10P15

10P10

200/1

 

2.5

3.75

 

1

300/1

2

3.75

5

1

1.5

400/1

3.75

7.5

7.5

1.5

2

500/1

5

10

12.5

1.5

2

600/1

7.5

10

12.5

2

2.5

200/5

 

2.5

3.75

 

 

300/5

1.5

3.75

5

 

 

400/5

2.5

7.5

7.5

 

 

500/5

5

10

12.5

1

1.5

600/5

7.5

10

12.5